Calibration Wizard Two Line Method

Objective: Apply the two line calibration test to a known structure to validate the process.

  • Two Line Method
    • The DUT is a 30mm long transmission line.
    • The “fixtures” are edge mounted SMA connectors.
  • Calibration Wizard requires 3 input files for the “Two Line” Calibration:
    • DUT + fixtures +transmission line with length “l1”
    • DUT + fixtures + transmission line with length “l2”
    • DUT + fixtures


  • Calibration Wizard requires 3 input files for the “Two-Line” Calibration:
    • DUT + fixtures +transmission line with length “l1” = 7.5mm

    • DUT + fixtures + transmission line with length “l2” = 15mm

  • Using the built-in Calibration Wizard in ANSYS Electronic desktop
    • Open Calibration Wizard under Tools --> Calibration Wizard

  • Result Comparison